ESTONIAN ACADEMY
PUBLISHERS
eesti teaduste
akadeemia kirjastus
PUBLISHED
SINCE 1952
 
Proceeding cover
proceedings
of the estonian academy of sciences
ISSN 1736-7530 (Electronic)
ISSN 1736-6046 (Print)
Impact Factor (2022): 0.9
Removal of radionuclides from Estonian groundwater using aeration, oxidation, and filtration; pp. 58–64
PDF | doi: 10.3176/proc.2012.1.08

Authors
Liie Lumiste, Rein Munter, Johannes Sutt, Tiit Kivimäe, Toivo Eensalu
Abstract

Groundwater in the north-eastern suburb of Tallinn was analysed to determine the content of iron, manganese, sulphides, ammonia, and radionuclides (Ra226, Ra228) and total radioactivity. It was established that for several wells of the Cambrian–Vendian water layer the annual effective dose would exceed the EU guideline for drinking water (0.1 mSv/yr). The purpose was to find a technology for simultaneous purification of groundwater from iron, manganese, sulphides, ammonia, and some radionuclides (Ra226, Ra228). A pilot plant consisting of a Venturi-type aeration unit GDT (Gas-Degas Technology, Mazzei Corp., USA), an oxidation tank, and two-stage filtration columns was constructed. Several non-catalytic (Everzit Special Plus, sand) and catalytic filter materials (Filtersorb FMH, Pyrolox) were tested. Along the flow sheet from the aerator to the II stage filter outlet the pH, dissolved oxygen and carbon dioxide, turbidity, the content of iron, manganese, and ammonia were monitored, mainly by using spectrophotometry (HACH DR/2000). Radioactivity of water samples was determined by the Estonian Radiation Centre using the liquid scintillation counting method and g-spectrometry. It was established that by intensive aeration of groundwater followed by oxidation for a certain contact time and appropriate selection of filter materials of different properties, it was possible to remove together with iron and manganese also radium isotopes. The total effectiveness of the process was 90% removal of gross-alfa and 70% removal of gross-beta activity of groundwater. Since the uranium content in the well water was marginal and radon was almost totally (99%) removed in the degas separator, the total effective dose was calculated by Ra226 and Ra228. It was about 0.067 mSv/yr, which is lower than the EU DWD guideline (0.1 mSv/yr). The theoretical assumption that radionuclides were already removed with Fe(OH)3 flocks in the first filtration step was verified by examining wash water. The radioactivity of wash water containing precipitate and the filtered wash water were measured. Results showed 4.6 times higher gross-alfa and 5.3 times higher gross-beta activity in the water containing precipitate. The co-precipitation process, where MnO2 and Fe(OH)3 flocks played an essential role, resulted in simultaneous removal of radium isotopes. Co-precipitation of radium with MnO2 was more effective than with Fe(OH)3.

References

1. WEKNOW (Web-based European Knowledge Network on Water). 2005.

2. Savitskaja, L. Radionuclides in Estonian groundwater. Keskkonnatehnika, 1999, 3, 4–8 (in Estonian).

3. Forte, M., Rusconi, R., and Trotti, F. Technical Report. Estimation of concentrations of radionuclides in Estonian groundwaters and related health risks. Twinning Light Contract No. EE06-IB-TWP-ESC-03. Tallinn, Estonia, 2009.

4. Hodi, M., Polyak, K., and Hlavay, J. Removal of pollutants from drinking water by combined ion exchange and adsorption methods. Envir. Inter., 1995, 21, 325–331.
http://dx.doi.org/10.1016/0160-4120(95)00019-H

5. Camacho, L. M., Deng, S., and Parra, R. R. Uranium removal from groundwater by natural clinoptilolite zeolite: effects of pH and initial feed concentration. J. Hazard. Mater., 2010, 175, 393–398.
http://dx.doi.org/10.1016/j.jhazmat.2009.10.017

6. Crittender, J. C. Water Treatment – Principles and Design. John Wiley & Sons, New York, 2005.

7. Valentine, R., Splinter, R., and Mulholland, T. A study of possible economical ways of removing radium from drinking water. In EPA Project Summary. EPA/600/S2-88/009, Cincinnati OH, USA,1988, 1–10.

8. Patel, R. and Clifford, D. Radium removal from water by manganese dioxide adsorption and diatomaceous earth filtration. In EPA Project Summary. EPA/600/S2-91/063, Cincinnati OH, USA, 1992, 1–8.

  9. Faust, S. D. and Aly, O. M. Chemistry of Water Treatment. Lewis Publ., New York, 1998.

10. Sommerfeld, E. O. Iron and Manganese Removal Hand­book. AWWA, Denver, USA, 1999.

11. Germain, D. Radium removal options for small systems: a comparison of processes. In 3rd NSF International Symposium on Small Drinking Water and Wastewater Systems, Washington DC, USA, April 22–25, 2001, 57–66.

12. COUNCIL DIRECTIVE 98/83/EC of 3 November 1998 on the quality of water intended for human con­sumption.

13. WHO Guidelines for Drinking Water Quality. First addendum to third edition. Vol. 1, Recommendations – 3rd. 2006.

14. Elejalde, C., Herranz, M., Idoeta, R., Legarda, F., Romero, F., and Baeza, A. Retention of radium from thermal waters on sand filters and adsorbents. J. Hazard. Mater., 2007, 144, 645–648.
http://dx.doi.org/10.1016/j.jhazmat.2007.01.089

Back to Issue