CORROSION OF AIR PREHEATER TUBES OF OIL SHALE CFB BOILER. PART I. DEW POINT OF FLUE GAS AND LOW-TEMPERATURE CORROSION; pp. 5–12
PDF | doi: 10.3176/oil.2009.1.01

Authors
T. PIHU, H. ARRO, A. PRIKK, R. Rootamm, A. KONIST
Abstract

The damage to air preheater (APH) tubes in the zones where air and gas temperatures are low discovered in CFB boilers at Estonian oil shale power plants was indicative of low-temperature corrosion (LTC). To establish damage causes, samples of ash deposits from boiler heating surfaces and APH corroded tubes were collected and chemically analysed, visual observations were conducted, dew point of flue gas was experimentally determined and deposit samples were collected also in the gas flue of a working boiler.

    The measured dew-point temperature of sulphuric acid in a pulverized firing (PF) boiler is 75–80 °C. The maximum chlorine content of the deposits collected from a probe tip inserted in a PF boiler’s gas flue is ~6%. The measured dew-point temperature in a CFB boiler’s gas flue is 55–60 °C. If the probe tip was contaminated, dew-point temperature rose to 75–80 °C. Chlorine content of the deposit samples collected from a CFB boiler was ~3%. The estimated dew-point temperature of water steam with no sulphur in flue gas was 52.0–53.4 °C in the following conditions: Qri = 8.30–8.50 MJ/kg, Wri = 11–14% and a = 1.20 (O2 = 3.5%).

    Possible LTC causes were analysed and recommendations were offered concerning implementation of measures to reduce LTC. It became evident that the temperature of APH tube walls fell below the dew-point temperature of oil shale flue gas, causing condensation of the water steam present in flue gas on the tubes. If there is water, well-soluble chlorides form an aqueous solution or become liquefied (CaCl2 crystal hydrates), and that process causes intensive electrolytic LTC.

References

1. Tallermo, H., Tomann, E., Klevtsov, I., Bojarinova, T., Nuutre, M. Acceleration of 12Х1МФ steel high-temperature corrosion under influence of chlorine in ash deposits // Energia Teataja. 1997. Vol. 18, No. 4 [in Estonian].

2. Tallermo, H., Tomann, E., Klevtsov, I., Bojarinova, T., Nuutre, M. Non-corrosive properties of 13 CrMo 44 and 10 CrMo 910 steel in PF boilers at metal temperatures up to 540 °C // Energia Teataja. 1997. Vol. 23, No. 10 [in Estonian].

3. Ots, A., Gavrilov, A., Randmann, R. Study of contamination of low-temperature heating surfaces during firing Estonian oil shale // Teploenergetika. 1972. No. 11 [in Russian].

4. Moskovits, P. D. Low-temperature boiler corrosion and deposits – a literature review // Ind. Eng. Chem. 1959. Vol. 51, No. 10. P. 1305–1312.
doi:10.1021/ie50598a041

5. Thermal Calculations for Boiler Units. Normative Method / N. Kuznetsov et al. (eds.). Moscow: Energia Publishing House, 1973. P. 296 [in Russian].

6. Öpik, I. Influence of Oil Shale Mineral Matter on Boiler Operating Conditions. – Tallinn: ERK, 1961. P. 249 [in Russian].

7. Arro, H., Prikk, A., Pihu, T. Calculation of qualitative and quantitative composi­tion of Estonian oil shale and its combustion products. Part 1. Calculation on the basis of heating value // Fuel. 2003. Vol. 82, No. 18. P. 2179–2195.

8. Air Preheater Corrosion in CFB Boilers / T. Pihu, H. Arro, A. Prikk. Tallinn University of Technology, report. Tallinn, 2006, 27 pp. [in Estonian].